Valve
diagnostics can be done from a number
of data inputs
- Acoustic
(Vibration)
- Pressure
- Displacement
- Flow
Sensing
Testing
is primarily performed on a test stand,
but can be done on-line. On-line testing
would require lifting the valve to obtain
actual set pressure values.
On-line
testing can be performed to predict set
pressure valves without lfiting the valve
Acoustic
data reveals events such as chatter or
simmer. By simultaneously capturing the
pressure data, a correlation can be made
from this information to predict the
Set Pressure - This correlation is OEM-specific.
Calculations
are determined based on ASME Code requirements.
Safety
Valve (Steam), Safety Relief Valves (Compressible
or Incompressible mediums) and Relief
Valves (Incompressible Mediums)
Air,
Steam, Gas or Water